Hauptinhalt dieser Seite

Sprungmarken zu den verschiedenen Informationsbereichen der Seite:

Sie befinden sich hier: Aussteller & Produkte. Aussteller & Produkte 2011.

Gesamtübersicht der Produktkategorien

Gesamtübersicht der Produktkategorien

Hallenlageplan anzeigen

IST, Isci Sagligi Techizati Sanayi ve Ticaret Ltd. Sti.
Ostim Mah. Melih Gokcek B. 31 Cad. 2269 Sok 42/1-2
06374 Ostim/Ankara, Türkei

Telefon: +90-312 3 84 13 00
Fax: +90-312 3 41 73 03
http://www.ist.com.tr

Login

für Aussteller
für Besucher

Interaktiver Hallenplan

Produktinformationen
Produktkategorien
Produkt-
informationen
29.06.2011

ISTAIR FRESH AIR BREATHING SYSTEMS WITH COMPRESSOR AND PORTABLE BREATHING AIR SETS WITH CYLINDERS

These systems are used at various sectors for the necessity to work in confined spaces where oxygen content is below 19,5% and toxic gases exist.

System supplies breathable air to user. ISTAIR airline breathing system is indispensable for wide-range of sectors like as marine, shipyard, refinery, construction, municipality works, etc.

- SKID MOUNTED and TRAILER MOUNTED FRESH AIR BREATHING SYSTEMS WITH COMPRESSORS

- PORTABLE BREATHING AIR SETS WITH CYLINDERS

ARITAN GAS FILTERS

ARITAN gas filters are designed for full and half face masks and certified as per EN 14387. ARITAN Filters can be used with all types of half and full face masks which have EN 148-1 thread connection.

Filter Type

Main area of applications

Standard - Certification

A2

Organic gases and vapours with a boiling point above 65°C

EN 14387: 2004

B2

Inorganic Gases and vapours

EN 14387: 2004+ A1:2008

E2

Sulphur Dioxide and other acidic gases

EN 14387: 2004+ A1:2008

K2

Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2

Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Ammonia and organic ammonia derivatives , Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2P3

Solid and liquid particulates (dusts, fibres, mists, fumes, bacteria andvirus), Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

29.06.2011

ISTAIR FRESH AIR BREATHING SYSTEMS WITH COMPRESSOR AND PORTABLE BREATHING AIR SETS WITH CYLINDERS

These systems are used at various sectors for the necessity to work in confined spaces where oxygen content is below 19,5% and toxic gases exist.

System supplies breathable air to user. ISTAIR airline breathing system is indispensable for wide-range of sectors like as marine, shipyard, refinery, construction, municipality works, etc.

- SKID MOUNTED and TRAILER MOUNTED FRESH AIR BREATHING SYSTEMS WITH COMPRESSORS

- PORTABLE BREATHING AIR SETS WITH CYLINDERS

ARITAN GAS FILTERS

ARITAN gas filters are designed for full and half face masks and certified as per EN 14387. ARITAN Filters can be used with all types of half and full face masks which have EN 148-1 thread connection.

Filter Type

Main area of applications

Standard - Certification

A2

Organic gases and vapours with a boiling point above 65°C

EN 14387: 2004

B2

Inorganic Gases and vapours

EN 14387: 2004+ A1:2008

E2

Sulphur Dioxide and other acidic gases

EN 14387: 2004+ A1:2008

K2

Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2

Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Ammonia and organic ammonia derivatives , Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2P3

Solid and liquid particulates (dusts, fibres, mists, fumes, bacteria andvirus), Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

29.06.2011

ISTAIR FRESH AIR BREATHING SYSTEMS WITH COMPRESSOR AND PORTABLE BREATHING AIR SETS WITH CYLINDERS

These systems are used at various sectors for the necessity to work in confined spaces where oxygen content is below 19,5% and toxic gases exist.

System supplies breathable air to user. ISTAIR airline breathing system is indispensable for wide-range of sectors like as marine, shipyard, refinery, construction, municipality works, etc.

- SKID MOUNTED and TRAILER MOUNTED FRESH AIR BREATHING SYSTEMS WITH COMPRESSORS

- PORTABLE BREATHING AIR SETS WITH CYLINDERS

ARITAN GAS FILTERS

ARITAN gas filters are designed for full and half face masks and certified as per EN 14387. ARITAN Filters can be used with all types of half and full face masks which have EN 148-1 thread connection.

Filter Type

Main area of applications

Standard - Certification

A2

Organic gases and vapours with a boiling point above 65°C

EN 14387: 2004

B2

Inorganic Gases and vapours

EN 14387: 2004+ A1:2008

E2

Sulphur Dioxide and other acidic gases

EN 14387: 2004+ A1:2008

K2

Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2

Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Ammonia and organic ammonia derivatives , Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2P3

Solid and liquid particulates (dusts, fibres, mists, fumes, bacteria andvirus), Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

29.06.2011

ISTAIR FRESH AIR BREATHING SYSTEMS WITH COMPRESSOR AND PORTABLE BREATHING AIR SETS WITH CYLINDERS

These systems are used at various sectors for the necessity to work in confined spaces where oxygen content is below 19,5% and toxic gases exist.

System supplies breathable air to user. ISTAIR airline breathing system is indispensable for wide-range of sectors like as marine, shipyard, refinery, construction, municipality works, etc.

- SKID MOUNTED and TRAILER MOUNTED FRESH AIR BREATHING SYSTEMS WITH COMPRESSORS

- PORTABLE BREATHING AIR SETS WITH CYLINDERS

ARITAN GAS FILTERS

ARITAN gas filters are designed for full and half face masks and certified as per EN 14387. ARITAN Filters can be used with all types of half and full face masks which have EN 148-1 thread connection.

Filter Type

Main area of applications

Standard - Certification

A2

Organic gases and vapours with a boiling point above 65°C

EN 14387: 2004

B2

Inorganic Gases and vapours

EN 14387: 2004+ A1:2008

E2

Sulphur Dioxide and other acidic gases

EN 14387: 2004+ A1:2008

K2

Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2

Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Ammonia and organic ammonia derivatives , Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2P3

Solid and liquid particulates (dusts, fibres, mists, fumes, bacteria andvirus), Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

29.06.2011

ISTAIR FRESH AIR BREATHING SYSTEMS WITH COMPRESSOR AND PORTABLE BREATHING AIR SETS WITH CYLINDERS

These systems are used at various sectors for the necessity to work in confined spaces where oxygen content is below 19,5% and toxic gases exist.

System supplies breathable air to user. ISTAIR airline breathing system is indispensable for wide-range of sectors like as marine, shipyard, refinery, construction, municipality works, etc.

- SKID MOUNTED and TRAILER MOUNTED FRESH AIR BREATHING SYSTEMS WITH COMPRESSORS

- PORTABLE BREATHING AIR SETS WITH CYLINDERS

ARITAN GAS FILTERS

ARITAN gas filters are designed for full and half face masks and certified as per EN 14387. ARITAN Filters can be used with all types of half and full face masks which have EN 148-1 thread connection.

Filter Type

Main area of applications

Standard - Certification

A2

Organic gases and vapours with a boiling point above 65°C

EN 14387: 2004

B2

Inorganic Gases and vapours

EN 14387: 2004+ A1:2008

E2

Sulphur Dioxide and other acidic gases

EN 14387: 2004+ A1:2008

K2

Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2

Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Ammonia and organic ammonia derivatives , Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2P3

Solid and liquid particulates (dusts, fibres, mists, fumes, bacteria andvirus), Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

ISTAIR FRESH AIR BREATHING SYSTEMS WITH COMPRESSOR AND PORTABLE BREATHING AIR SETS WITH CYLINDERS

These systems are used at various sectors for the necessity to work in confined spaces where oxygen content is below 19,5% and toxic gases exist.

System supplies breathable air to user. ISTAIR airline breathing system is indispensable for wide-range of sectors like as marine, shipyard, refinery, construction, municipality works, etc.

- SKID MOUNTED and TRAILER MOUNTED FRESH AIR BREATHING SYSTEMS WITH COMPRESSORS

- PORTABLE BREATHING AIR SETS WITH CYLINDERS

ARITAN GAS FILTERS

ARITAN gas filters are designed for full and half face masks and certified as per EN 14387. ARITAN Filters can be used with all types of half and full face masks which have EN 148-1 thread connection.

Filter Type

Main area of applications

Standard - Certification

A2

Organic gases and vapours with a boiling point above 65°C

EN 14387: 2004

B2

Inorganic Gases and vapours

EN 14387: 2004+ A1:2008

E2

Sulphur Dioxide and other acidic gases

EN 14387: 2004+ A1:2008

K2

Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2

Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Ammonia and organic ammonia derivatives , Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008

A2B2E2K2P3

Solid and liquid particulates (dusts, fibres, mists, fumes, bacteria andvirus), Organic gases and vapours with a boiling point above 65°C, Inorganic Gases and vapours, Sulphur Dioxide and other acidic gases, Ammonia and organic ammonia derivatives

EN 14387: 2004+ A1:2008


29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.

29.06.2011

HEAT AND FIRE PROTECTIVE GARMENTS

IST. Ltd. Co. releases technical firefighting garments to the market in the brand of FYRPRO and aluminized garments, which are used in different firefighting techniques, in the brand of FYRAL.

Basically, EN 469 standard defines the lowest limits of fire resistance of different heat types, and also includes the lowest value of the garment against water pressure and highest resistance values against water vapor permeance. They are categorized as Level 1 and Level 2 according these factors. Level 2 Garments provides the best protection and maximum comfort. IST has wide range of Level 2 garments in different layers.

Main purpose in fireman garments is the protection of the user against heat stress. This is provided by using the high heat resistant layers and keeping the user dry. The greatest aid in the firefighting "Water" is fatal if stays on the firefighter.

Garments are generally formed with 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Moisture Barrier (PU membrane laminated on Aramid based conductor.)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

FYRAL Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire.

FYRAL series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE.

Garments are formed with 3 or 4 main layers.

- Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent)

- Heat Barrier (double or single layered , generally non-woven fire resistant layer)

- Inner Liner ( quilted on heat barrier, low weight fire resistant fabric)

Moisture Barrier can be added according to area of use.

We also have different garments for heat protective garments in industrial applications, molten metal splash garments and electrical arc protective garments.

FYRTEX® HEAT & MOLTEN METAL SPLASH PROTECTIVE GARMENTS FOR INDUSTRIAL APPLICATIONS: Harmonized EN ISO 11612,EN 1149-5(EN 1149-3 & EN 1149-1)

ELECTPRO® ELECTRICAL ARC PROTECTIVE GARMENTS: Harmonized EN 61482-1-2 & EN ISO 11612

All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive.


27.06.2011

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

 

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.

29.06.2011

EMERGENCY SHOWERS AND EYE WASH FOUNTAINS

Eye wash fountains and Emergency showers are designed and intended to be installed in close range of persons working in a potentially hazardous areas where acids, caustics, or any other dangerous and corrosive agents are nearby. The main purpose of these devices is to immediately deliver fluid in a sufficient volume to extinguish flames and/or to flush the body following exposure to injurious substances or heat. With this accomplished the injured person can proceed to medical care. Fatal injuries and deaths can be prevented by using emergency safety showers.

All of our Emergency Showers fulfill the standards of EN 15154-1 and / or EN 15154-2.

Various models according to your needs:

- Counter Top Mounted

- Wall Mounted,

- Pedestal mounted

- Freeze Proof

- Combined Showers and Eye Wash Fountains.

Showers can be produced in stainless steel or galvanized and painted. Color is optional in galvanized and painted models; they can be painted according to your request.

Emergency Safety Showers and Eye wash fountains and Combined Units can also be supplied in Freeze Proof with auto-leak valves and underground valves.


29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil

29.06.2011

SAFETY CANS

Safety Cans are designed to contain and transport hazardous liquids and control vapors to reduce the risk of fire, consequently protecting both personnel and facilities.

Nearly in all business sectors and even at home, flammable and combustible liquids like petrol, various chemicals, solvents, are occasionally used.

To minimize the risk of accidents safety cans must be used as a milestone in containing these types of liquids.

- Allows easy filling and effortless pouring.
- Easy to carry and unfill spring cover mechanism
- Durable and protective electro-static powder paint ( in galvanized models)
- Polished Surfaces ( in stainless steel models)
- Reinforced body for impacts
- Bottom end, Seamed with Weld and reinforced with clamp
- Different models with different sizes

Color Codes
Red : Inflammable solvents
Blue : Kerosene
Yellow : Diesel, petrol and fuel
Green : Oil